BFI-P2-62-1500-3F4N-MN

Article number 60169

  • Output power 37 kW
  • Output 3x230 VAC, 150 A
  • Input voltage 3x200-240 VAC
  • IP55
Contact Print (PDF)

Facts

General description

Article number 60169
Warranty 2 year

Mechanical

IP class IP55
Physical size Size 6
Measurements (H x W x D) 865 mm x 330 mm x 330 mm
Weight 55 kg
Typical power loss at rated power 2 % of rated power
Main switch No
Built in Main switch, control switch and potentiometer No
Conformal coated PCBs Yes, IEC 60721-3-3, 3S3/3C3

Output ratings

Output voltage 3 x 230 VAC
Rated motor current 150 A
Overload capacity 150% for 60 seconds, 200% for 4 seconds
Motor power 37 kW
Output frequency 0 – 500Hz, 0.1Hz resolution
Supported motor types 3 phase AC induction (IM), AC permanent magnet (PM), Brushless DC (BLDC), Synchronous reluctance (SynRM)
Built-in brake transistor Yes
Regenerative capacity 100 % ED

Input ratings

Supply voltage 200 – 240VAC ± 10%
Voltage fluctuations +/- 10%
Phase imbalance 3% maximum allowed
Displacement factor > 0.98
Supply frequency 48 – 62Hz
Power cycles 120 per hour maximum, evenly spaced

Control specification

Control modes V/F Voltage Vector, Energy Optimised V/F, Sensorless Vector Speed Control, Sensorless Vector Torque Control, Synchronous Reluctance Motor Control, Brushless DC Motor Control, Closed Loop (Encoder) Speed Control, Closed Loop (Encoder) Torque Control, Open Loop PM Vector Control
Current/torque limitation Torque and current limitation
PWM frequency 4-32 kHz effective
Stopping mode Ramp to Stop: User Adjustable 0.1 – 6000 seconds. Fast stop. Coast to Stop
Braking Motor Flux Braking, Built-in Braking Transistor
Skip frequency Yes
Analog setpoint control 0 to 10V, 10 to 0V, −10 to 10V, 0 to 20mA, 20 to 0mA, 4 to 20mA, 20 to 4mA
Digital setpoint control 8 fixed speeds, Motorised Potentiometer, Internal PLC, Keypad, Modbus RTU, CANopen, Optional: PROFIBUS DP, DeviceNet, EtherNet/IP, EtherCat, PROFINET, Modbus TCP, CC-Link

Communication

Modbus RTU Yes, 9.6 - 115.2 kbps (8N1, 8N2, 8E1, 8O1)
BACnet MS/TP No
Modbus TCP Yes, external option
Ethernet IP Yes, external option
EtherCat Yes, external option
Profinet IO Yes, external option
Profibus DP(DPV1) Yes, external option
Device Net Yes, external option
CC-Link Yes, external option
CAN open Yes, 125-1000 kbps

Display

Programmable display Yes
Multi language OLED display TFT Display
External OLED display Yes, TFT Display
LED display No

HVAC

PID-control Yes with sleep/wake up functionality
Spin start Yes
Pump dry protection No
Pump prime and burst protection No
Stir function No
Motor pre-heat No
Broken impeller and broken belt detection No
Automatic cleaning for pumps No
Bypass control Yes
Fire mode No

Control terminals

Power supply 100 mA @ 24 VDC, 20 mA @ 10 VDC
Inputs 5 in total, 3 Digital, 2 Analog or Digital, selectable
Digital inputs 10-30 V DC, PNP, Response time: < 4 msec, Internal or external supply
Analog inputs Resolution:12 bit, Response time: <4 msec; Accuracy: <± 2% of full scale, Adjustable scaling
Outputs 4 total, 2 relays, 2 analog or digital
Digital transistor outputs 24VDC/20 mA, Internal supply
Relay outputs Maximum Voltage: 250 VAC, 30 VDC Switching Current Capacity: 5A AC, 5A DC
Analog outputs 0 to 10 Volt, 0 to 20mA, 4 to 20mA
Safety inputs 2
Extra IOs Yes, internal option

Control features

Speed control Master/slave Yes, Master and slave
Modbus master functionality Yes, Master and slave
Advanced hoist control Yes
Built-in PLC Yes

Standard compliances

Low voltage directive 2014/35/EU
EMC directive 2014/30/EU
Conformance CE, UL, cUL
Machine directive 98/37/EC
Marine approvals DNV
Safe torque OFF Cat 3/PL"d" According to ISO 13849-1, SIL CL 2 According to EN61800-5-2 / EN62061 / IEC61508
Restriction of hazardous substances RoHS2
Registration evaluation and authorisation of chemicals Reach
Earth leakage current EN 61800-5-1: 2007. Test techniques EN 60990:2000. 1x230 VA < 2,5 mA, 3x400VAC < 4,65 during runing
DC Bus discharge time EN 61800-5-1:2007
Electrostatic discharge EN 61800-3:2004+A1-2012. Test techniques EN 61000-4-2:2009.
Dielectric strength 61800-5-1: 2007
Surge EN 61800-3: 2004+A1-2012. Test techniques EN 61000-4-5:2006.
Electrical fast transient burst EN 61800-3: 2004+A1-2012. Test techniques EN 61000-4-4:2004.

Ambient conditions

Temperature operation -10 to 40 °C
Humidity 95% max, non-condensing

Maintenance

Fault memory Last 4 Trips stored with time stamp
Data logging Logging of data prior to trip, Current, Temperature, DC Bus Voltage
Maintenence indicator Yes. Onboard service life monitoring
Monitoring Hours Run Meter, kWh/MWh meter

Resources

Knowledge

File name Date
​​Alarm, Excessive DC rippel 2022-09-20 08:42:32
Alarm code running single phase motor with 3-phase output BFI 2022-10-05 14:15:33
BFI - Clarifications of BFI SmartStick options 2024-03-22 12:09:19
Modbus TCP gateway OPT-3-MTPEG-BFI - Reset IP address to default 2023-06-21 10:24:55
Problems with EMC noise 2023-06-21 13:41:56
BFI-P2 and BFI-H3. Manual Run from Keypad. 2023-06-21 10:31:54
24 VAC connected to terminal 1 will damaged the drive 2022-09-26 15:29:00
BFI - Radiated and conducted emissions 2024-03-22 13:14:05
Cooling fans in the BFI-P2 2022-10-05 14:16:17
BFI-H3 BFI-P2 Auto Reset after trip 2024-08-08 13:33:03
Input Phase Loss Detection 2022-11-16 17:03:47
Application note BFI-P2, Using The Display Scaling Function 2023-01-26 14:30:36
Application note BFI-P2, Use of Drive on generator supplies 2023-01-26 14:30:36
Alternate between EtherNet control and Digital/analog 2022-10-05 15:18:41
Overcurrent trip 2022-10-05 15:17:58
Main switch in IP66 BFI-P2, BFI-E3 and BFI-H3 2024-08-08 13:38:20
Default network settings OPT-3-MTPEG-BFI and BFI-E3-MTP 2024-01-16 11:19:54
OLED Remote External Keypad, Working with Multiple Drive Networks 2022-10-05 15:02:58
Power consumption in standby 2022-10-05 14:15:54
Single phase motors run by BFI-E3/H3/P2 2022-10-05 14:14:55
Fans, external cooling fans 2022-10-05 14:15:53
PID-control. Scaling of actual processvalue in display and unit 2022-10-05 14:15:55
Automatic heating of BFI-P2 when temperatur is below -10 degree Celsius 2022-10-06 14:34:41
BFI - User-defined process data for cyclic data exchange 2024-01-02 13:22:15
Modbus RTU and Modbus TCP communication at the same time 2022-10-05 15:11:16
Encoder feedback 2022-10-05 15:17:58
Thermal protection inside motor connected to BFI-E3/P2/H3 2022-09-26 15:29:02
BFI as DC / AC Converter 2022-10-05 15:17:58
BFI reset to Parameter Factory Default Settings 2024-08-08 13:36:12
Brakeresistor duty cycle in BFI-P2 2024-09-04 10:40:08
CanOpen and Modbus RTU simultaneosly 2024-06-20 09:57:20
Application note BFI-P2, Selecting the Start - Restart Mode 2023-01-26 14:30:35
Application note BFI-P2, Scaling of displayed value 2023-01-26 14:30:35
​​Application note BFI-P2, Remote Push-button Speed Control 2023-01-26 14:31:04
Application note BFI-P2, Programming the Drive User Relays 2023-01-26 14:30:36
​​Application note BFI-P2, Permanent Magnet and Brushless DC Motor Control 2023-01-26 14:30:42
Application note BFI-P2, Mounting Drives in control panels 2023-01-26 14:30:37
Application Note: BFI-P2, Modifying the Constant V-F Output characteristic 2023-01-26 14:31:04
​​Application note BFI-P2, Master Slave Network Operation 2023-01-26 14:30:43
​​Application note BFI-P2, Hoist Applications 2023-01-26 14:30:43
​​Application note BFI-P2, High Frequency Firmware 2023-01-26 14:30:43
​​Application note BFI-P2, Fan components in Drive construction 2023-01-26 14:30:42
Application note BFI-P2, Encoder-less Vector Control for 3 Phase Induction Motors 2023-01-26 14:30:36
​​Application note BFI-P2, Displaying Motor Speed in rpm 2023-01-26 14:30:38
​​Application note BFI-P2, Setting Required Stopping Mode 2023-01-26 14:30:38
​​Application note BFI-P2, Locking Parameters to Prevent Changes 2023-01-26 14:30:38
​​Application note BFI-P2, Setting Motor nameplate Details 2023-01-26 14:30:37
Application note BFI-P2, Skip Frequency function 2023-01-26 14:30:35
​​Application note BFI-P2, Using Multiple Motor in Parallel 2023-01-26 14:30:43
CC-Link communication 2022-10-05 14:15:54
BFI Tools wants to Update in Windows 10 2023-09-21 14:56:42
BFI P2 IP66 low temp trip. 2024-02-21 12:30:32
Limited availability

BFI-P2-62-1500-3F4N-MN

Article number 60169


EOL - End Of Life:
-

LTB - Last Time Buy:
-

LTD - Last Time Delivery:
-

LTR - Last Time Repair:
-

Replacement Parts: