BFI-E2-22-0070-3F42

Article number 61130

  • Output power 1.5 kW
  • Output 3x230 VAC, 7.0 A
  • Input voltage 3x200-240 VAC
  • IP20
Contact Print (PDF)

Facts

General description

Article number 61130

Mechanical

IP class IP20
Physical size Size 2
Measurements (H x W x D) 221 mm x 110 mm x 150 mm
Weight 1.7 kg
Typical power loss at rated power 0,02
Main switch No
Built in Main switch, control switch and potentiometer No
Conformal coated PCBs No

Output ratings

Output voltage 3 x 230 VAC
Rated motor current 7.0 A
Overload capacity 150% for 60 seconds, 175% for 2 seconds
Motor power 1.5 kW
Output frequency 0 – 250Hz, 0.1Hz resolution
Supported motor types 3 phase AC induction (IM), AC permanent magnet (PM), Brushless DC (BLDC), Synchronous reluctance (SynRM)
Built-in brake transistor Yes
Regenerative capacity 100 % ED

Input ratings

Supply voltage 200 – 240VAC ± 10%
Voltage fluctuations +/- 10%
Phase imbalance 3% maximum allowed
Displacement factor > 0.98
Supply frequency 48 – 62Hz
Power cycles 120 per hour maximum, evenly spaced
Total harmonic current distorsion No

Control specification

Control modes V/F Voltage Vector, Energy Optimised V/F
Current/torque limitation No
PWM frequency 4-32 kHz effective
Stopping mode Ramp to Stop: User Adjustable 0.1 – 600 seconds,Coast to Stop
Braking Built-in Braking Transistor
Skip frequency No
Analog setpoint control 0 to 10V, 0 to 20mA, 4 to 20mA, 20 to 4mA
Digital setpoint control 4 fixed speeds, Motorised Potentiometer, Keypad, Modbus RTU

Communication

Modbus RTU 9.6 - 115.2 kbps selectable (8N1, 8N2, 8E1, 8O1)
BACnet MS/TP No
Modbus TCP No
Ethernet IP No
EtherCat No
Profinet IO No
Profibus DP(DPV1) No
Device Net No
CC-Link No
CAN open No

Display

Programmable display No
Multi language OLED display No
External OLED display Yes
LED display Yes

HVAC

PID-control PI-control with sleep/wake up
Spin start Yes
Pump dry protection No
Pump prime and burst protection No
Stir function No
Motor pre-heat No
Broken impeller and broken belt detection No
Automatic cleaning for pumps No
Bypass control Yes
Fire mode No

Control terminals

Power supply 100 mA @ 24 VDC, 20 mA @ 10 VDC
Inputs 4 in total, 2 Digital, 2 Analog or Digital, selectable
Digital inputs 8-30 V DC, PNP, Response time: < 4 msec, Internal or external supply
Analog inputs Resolution:12 bit, Response time: <4 msec; Accuracy: <± 2% of full scale, Adjustable scaling
Outputs 2 total, 1 relay, 1 analog or digital
Digital transistor outputs 24VDC/20 mA, Internal supply
Relay outputs Maximum Voltage: 250 VAC, 30 VDC Switching Current Capacity: 6A AC, 5A DC
Analog outputs 0 to 10 Volt, 0 to 20mA, 4 to 20mA
Safety inputs No
Extra IOs No

Control features

Speed control Master/slave No
Modbus master functionality No
Advanced hoist control No
Built-in PLC No

Standard compliances

Low voltage directive Adjustable speed electrical power drive systems. EMC requirements
EMC directive 2004/108/EC, Cat C1 according to EN 61800-3:2004
Conformance CE, UL
Machine directive 2006/42/EC
Marine approvals No
Safe torque OFF No
Restriction of hazardous substances RoHS2
Registration evaluation and authorisation of chemicals Reach
Earth leakage current EN 61800-5-1: 2007. Test techniques EN 60990:2000. 1x230 VA < 2,5 mA, 3x400VAC < 4,65 during runing
DC Bus discharge time EN 61800-5-1:2007
Electrostatic discharge EN 61800-3:2004+A1-2012. Test techniques EN 61000-4-2:2009.
Dielectric strength 61800-5-1: 2007
Surge EN 61800-3: 2004+A1-2012. Test techniques EN 61000-4-5:2006.
Electrical fast transient burst EN 61800-3: 2004+A1-2012. Test techniques EN 61000-4-4:2004.

Ambient conditions

Temperature operation -10 to 50 °C
Humidity 95% max, non-condensing

Maintenance

Fault memory No
Data logging Logging of data prior to trip, Current, Temperature, DC Bus Voltage
Maintenence indicator No
Monitoring Hours Run Meter, kWh meter