X2 extreme 15 SL HP
15'' Rugged sealed HMI with iX runtime
- 1280 × 800 pixel (16:10) TFT-LCD touch screen
- High brightness display
- M12 connectors - IP66
- Ethernet 2x100 Mbit
- -30°C to +70°C operating temperature
- DNV GL, KR, LR, ABS, CCS, BV, NK, RS marine approvals
- UL Class I Div 2, ATEX/IECEx Zone 2,22
Facts
General description
Part number | 640014805 |
Life cycle status | Active |
Warranty | 2 year |
Certifications
General | CE, FCC, KCC, UL 61010-2-201, UL 746C |
Hazardous | ULC1D2, ATEX (Zone2), ATEX (Zone22), IECEx (Zone2), IECEx (Zone22) |
Marine | KR, LR, ABS, CCS, BV, NK, DNV GL, RS |
Mechanical
Mechanical size | 410 x 286 x 65mm |
Mounting option | VESA 100 x 100 |
Number of touches | 1million finger touch operations |
Touch type | Resistive |
Cut-out size | N/A |
Weight | 4.8 kg |
Housing material | Powder-coated aluminum, Black |
Power
Input voltage | 24 VDC (18 to 32 VDC) CE: The power supply must conformwith the requirements according to IEC 60950 and IEC 61558-2-4.UL and cUL: The power supply must conform with the requirements for class 2 power supplies. |
Power consumption (max) | 28 W |
Input fuse | Internal DC fuse |
System
CPU | i.MX6Quad, Quad ARMCortex-A9 1.0GHz 1MBL2cache |
RAM | 2 GB |
FLASH | 4GB SSD(eMMC), 3.5GB free for application |
Display
Size diagonal | 15.4" diagonal |
Resolution | 1280x800 pixels |
Backlight | LED Backlight |
Backlight life time | 100000 hours |
Backlight brightness | 1000 cd/m2 |
Backlight dimming | Marine optimized dimming |
Display type | TFT-LCD with LED backlight |
Serial communication
Number of serial ports | 2 Port 8pin M12 |
Serial port 1 | RS 232 |
Serial port 2 | RS422/RS485/CAN |
Serial port 3 | RS485/CAN |
Ethernet communication
Number of Ethernet ports | 2 |
Ethernet port 1 | 1x10/100 Base-T (4 pin M12) |
Ethernet port 2 | 1x10/100 Base-T (4 pin M12) |
Communication CAN
Number of CAN ports | 2 |
CAN port 1 | 1 Mbit |
CAN port 2 | 1 Mbit |
Expansion interface
SD card | SD and SDHC |
USB | 2xUSB 2.0 500mA |
Environmental
Operating temperature | -30°C to +70°C |
Storage temperature | -40°C to +80°C |
Shock | 40g, half-sine, 11ms according to IEC60068-2-27 |
Vibration | 4g, according to IEC 60068-2-6, Test Fc |
Sealing front | IP66 (IP65 for ATEX/IECEx) |
Sealing back | IP66 (IP65 for ATEX/IECEx) |
Humidity | 5% – 95% non-condensed |
Altitude (max) | < 3000m |
Drivers
ABB - COMLI Master (5.7.2) |
ABB - COMLI Slave (4.11.0) |
ABB - TotalFlow (5.2.1) |
Allen Bradley - ControlLogix Ethernet IP (4.24.1) |
Allen Bradley - DF1 (5.8.0) |
Allen Bradley - DH485 (4.6.2) |
Allen Bradley - MicroLogix Ethernet (5.6.0) |
Allen Bradley - SLC5/PLC5 Ethernet (5.4.0) |
Altus - Alnet I (5.8.0) |
Animatics - SmartMotor (5.2.1) |
Beckhoff - ADS (5.12.1) |
Beckhoff - ADS Symbolic (4.7.0) |
Beijer Electronics - iX Demo (4.4.0) |
Bernecker + Rainer - Mininet (5.6.0) |
BoschRexroth - IndraDrive C (5.2.1) |
CODESYS - ARTI v2.x, v3.x (4.8.0) |
CODESYS - SoftControl Direct Access (4.4.0) |
Cognex - InSight (5.2.2) |
Control Techniques - Unidrive (5.3.1) |
CTC - Serial Binary (5.4.2) |
Delta - PLC Modbus ASCII (5.6.0) |
Emerson - DNP3 (4.8.2) |
Emerson - Modbus Master RTU/ASCII (5.4.0) |
Eurotherm - Easy Serial 631 (5.1.1) |
Fatek - Facon (5.10.0) |
Galil - DMC (5.2.2) |
GE Fanuc - Ethernet SRTP (5.5.0) |
GE Fanuc - SNPX (5.6.1) |
Gidding & Lewis - Motion control (5.4.0) |
IAI - Xsel (5.4.1) |
Idec - Computer Link (5.8.0) |
Johnson Control - JCONTROL (5.2.1) |
KEB - COMBIVERT (5.4.0) |
Keyence - KV-series (5.6.0) |
Koyo - DirectNET (5.5.0) |
Koyo - K Sequence (5.3.1) |
Lenze - LECOM A/B (5.6.0) |
LS Industrial System - Glofa (5.3.0) |
LS Industrial System - Master K (5.4.0) |
Matsushita - MEWTOCOL-COM (5.9.2) |
Mitsubishi Electric - Alpha2 (5.7.0) |
Mitsubishi Electric - A-series (C24) (5.6.0) |
Mitsubishi Electric - A-series (CPU) (5.10.0) |
Mitsubishi Electric - A-series (E71) (5.4.0) |
Mitsubishi Electric - Freqrol FR-A PLC (5.8.2) |
Mitsubishi Electric - FX Series ADP/BD (5.10.0) |
Mitsubishi Electric - FX Series ENET (5.4.1) |
Mitsubishi Electric - FX Series Serial (5.16.0) |
Mitsubishi Electric - MC Protocol (5.11.4) |
Mitsubishi Electric - MR-J2/MR-J3-T MELSERVO (5.9.0) |
Mitsubishi Electric - QnA/Qnn Serial (5.10.0) |
Mitsubishi Electric - QnA/Qnn (C24) (5.5.0) |
Mitsubishi Electric - Q-Series Ethernet (E71) (5.5.0) |
Modicon - Modbus Master (5.19.4) |
Modicon - Modbus Slave RTU/TCP (4.20.2) |
NEMA0183 - NEMA 0183 (4.6.0) |
Omron - Ethernet IP (4.3.3) |
Omron - FINS (5.9.5) |
Omron - Host Link (5.6.0) |
Regin - EXOline (5.3.2) |
SAIA - S-BUS Serial/Ethernet (5.7.0) |
Schneider Electric - Modbus (5.3.0) |
Schneider Electric - TSX Uni-Telway (4.5.3) |
Siemens - S7 200 PPI (5.8.5) |
Siemens - S7 over TCP (S7-200/300/400/1200/1500) (4.18.0) |
Siemens - MPI (HMI Adapter) (5.7.0) |
WAGO - Modbus TCP (5.10.0) |
Vigor - M/VB-Series (5.6.0) |
Yamaha - VIP (5.2.1) |
Yaskawa - Memobus Master (5.7.0) |
Yokogawa - FA-M3 (5.6.0) |
Smart Engineering Resources
Resources
Knowledge
- IX otf and ttf fonts
- iX Developer SP7 - 2.47.473 Release information
- Driver MODICON Modbus Slave: Command XDNCW
- Windows CE versions, X2, iX, E1000
- Creating a custom Welcome Screen \ startup screen on a X2 pro operator panel
- iX - SMTP - Using Gmail servers using App password
- OPC ua settings in Phoenix plxnext engineer
- Image Sticking
- Best Practice Database on SD card or flash memory
- Quick start guide, Disable / Suppress Flashwear warning dialogue on X2 series SUEN00411
- Max number of recipe items / tags
- Convert from Exter/E1000 To X2 Series
- X2 pro / X2 marine / BoX2 pro image V2.1 HF b909 (current)
- X2 image - Update EBOOT require SD card to be formatted to FAT16/FAT32
- Nexto Xpress - Program example CANopen X2 Extreme as slave device
- Viewing angle X2 series
Manuals
- iX Developer SP7 - 2.47.473 Reference Manual
- iX Developer SP7 - 2.47.473 User guide
- X2/Box2 image manual MAEN205
- New manuals for protection class ec
- X2 Extreme CO Manuals
- Installation manual for X2 extreme panel mount terminals, MAEN239
- Installation manual X2 extreme 15 SL HP, MAEN263
Certificates
- DoC ECCN for X2 series HMI
- SDoC Green Passport
- Environmental Impact Report X2 pro, X2 marine, X2 control, X2 motion
- DNVGL Type Approval Certificate X2 extreme sealed
- DNVGL Type Approval Certificate X2 extreme
- ABS Type Approval Certificate X2 extreme sealed
- ABS Type Approval Certificate X2 extreme
- LR Type Approval Certificate X2 extreme
- LR Type Approval Certificate X2 extreme sealed
- Compass safe distance X2 extreme
- X2 extreme (SC) / X2 extreme sealed (SC) / BoX2 extreme (SC), CE manufacturer declaration
- X2 extreme (SC) / BoX2 extreme (SC), CCC ex-zone
- Manufacturer declaration: X2 extreme UKCA Declaration of Conformity
- IECEx Certificate X2 extreme (SC) / BoX2 extreme (SC)
- CCS Type Approval Certificate X2 extreme sealed
- CCS Type Approval Certificate X2 extreme
- CE Manufacturer declaration X2 extreme and X2 extreme sealed
- DoC CE, EMC, RoHS Declaration of conformity X2 extreme
- ATEX Certificate X2 extreme, X2 extreme sealed, Box2 extreme
- BV Type Approval Certificate X2 extreme
- BV Type Approval Certificate X2 extreme sealed
- CCS Marine Certificate X2 extreme, pro, control, marine
- KR Type Approval Certificate X2 extreme sealed
- KR Type Approval Certificate X2 extreme
- NKK Type Approval Certificate X2 extreme sealed
- NKK Type Approval Certificate X2 extreme
- X2 extreme (SC) / BoX2 extreme (SC) update IECEx ATEX 2021
- DNV Type Approval Certificate X2 Extreme SL
- CE Certificate X2 extreme 15 SL HP
- EN 60945 Certificate X2 extreme 15 SL HP
Drawings
- Cable CAB113: Cable for ModBus RS485 between X2 panel and BFI
- Outline drawings, X2 extreme 7, 12, 15
- Cutout drawings, X2 extreme 7, 12, 15
- CAB153 Cable Drawing for X2 base, X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B/C operator panel
- CAB150 Cable Drawing for X2 base, X2 pro, X2 marine, X2 control, iX Panel TxA/B/C operator panel
- CAB101 Cable Drawing for X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B/C operator panel
- CAB100 Cable Drawing for X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B/C operator panel
- 3D drawing, X2 extreme 15 (standard, high-performance and fully sealed versions) in STEP format
Drivers
Brochures
Product information
- MTBF Summary X2 pro, X2 control, X2 motion, X2 marine
- X2 export control and dual use
- X2 Letter of Volatility
- Battery test summary - X2 extreme
- Environmental Impact Report X2 extreme
- MTBF summary X2 extreme
Software
- AdAuth - iX user authentication with LDAP in domain / Active Directory
- iX Developer SP7 - 2.47.473 Software
- SqlProxy - Connects iX Panels transparently to SQL Server
- Remote Access Viewer v1.5.4, for Exter/E1000 - TxA/TxB/TAxx - X2 panels
- FTDI Direct driver demo
Program examples/Start-up
- X2 Date time picker script
- IX alarm info request lookup in pdf by page index
- Program example iX Developer: Modbus TCP communication between any X2 and BFI-P2/H3.
- Program example iX Developer: Modbus RTU communication between any X2 and BFI-E3, BFI-P2 or BFI-H3.
- iX Templates for E-key and X-Key
- Add Tags to Tagmonitor by script
- Quick start guide - Connect X2 HMI with Nexto PLC, SUEN00414
- Ping from IX x2 terminal
- iX Developer - Top10 Alarm list, based on count and/or duration
- Quick Start Guide, MELSEC FX5U/FX5UC Ethernet to X2 series, SUEN00402
- Quick Start Guide, MELSEC Qnn QJ71E71 Ethernet to X2 series SUEN405
- Quick Start Guide, MELSEC iQ-R Ethernet - X2 series SUEN00406
- Quick Start Guide, MELSEC QnUDE Ethernet to X2 series, SUEN00403
Information document
Configuration files
System program
Limited availability
X2 extreme 15 SL HP
15'' Rugged sealed HMI with iX runtime
EOL - End Of Life:
-
LTB - Last Time Buy:
-
LTD - Last Time Delivery:
-
LTR - Last Time Repair:
-
Replacement Parts: