Facts
General description
Part number | 601110026 |
Life cycle status | Limited |
Warranty | 1 year |
Mechanical
Mechanical size | 285 x 177 x 62 mm |
Cut-out size | 246 x 139 mm |
Weight | 1.4 kg |
Housing material | Powder-coated aluminium, grey |
Power
Input voltage | 20 - 30 V DC |
Power consumption (max) | 9,6 W |
Input fuse | Internal DC fuse, 3.15 AT |
Display
Size diagonal | 6.5 inch |
Resolution | 640 x 480 pixels |
Backlight | CCFL with dimming |
Backlight life time | 50,000 hrs |
Backlight brightness | 350 cd/m2 |
Display type | TFT CCFL |
Serial communication
Number of serial ports | 1 Port 9pin DSUB/1 Port 25 pin DSUB |
Serial port 1 | RS 232 (RTS/CTS) |
Serial port 2 | RS422 (RTS)/RS485 |
Ethernet communication
Number of Ethernet ports | 1 |
Ethernet port 1 | 1x10/100 Base-T (shielded RJ45) |
Resources
- 03330: Control Techniques Unidrive to CIMREX and EXTER / E- and E1000 Series via CAB8. RS422
- 03331: Control Techniques Unidrive to CIMREX and EXTER / E- and E1000 Series. RS422
- 03332: Control Techniques Unidrive to CIMREX and EXTER / E- and E1000 Series Point-to-Point. RS422
- 03333: Toshiba PROSEC T-Series to CIMREX and EXTER /E- and E1000 Series. RS422
- 03334: Toshiba PROSEC T-Series to CIMREX and EXTER / E- and E1000 Series with CAB12. RS232
- 03337: Idec Micro to CIMREX and EXTER / E- and E1000 Series via CAB8. RS422
- 03338: Idec Micro to CIMREX and EXTER / E- and E1000 Series via CAB8. Screw Connectors. RS422
- 03339: Idec Micro to CIMREX and EXTER / E- and E1000 Series. RS232
- 03341: Atlas Copco DMC to CIMREX and EXTER /E- and E1000 Series. RS422
- 03342: Koyo DL-Series to CIMREX and EXTER / E- and E1000 Series with CAB12. DB9 to DB15. RS232
- 03343: Koyo DL-Series to CIMREX and EXTER /E- and E1000 Series with CAB12. RJ12 to DB9F. RS232
- 03344: Koyo DL-Series to CIMREX and EXTER / E- and E1000 Series. DB25 to DB15. RS422
- 03349: Matsushita FP3 to CIMREX and EXTER / E- and E1000 Series. RS422
- 05005: Communication Ports EXTER / E1000 Series
- 05210: Telemecanique TSX Nano/Micro/Premium to EXTER / E1000 Series. RS485
- 05230: Koyo DL-Series to EXTER / E1000 Series. RS232
- 05234: Koyo DL-Series (RJ12) to EXTER / E1000 Series
- 05235: Matsushita FP1 to EXTER / E1000 Series. DB9M to DB9F. RS232
- 05236: Mitsubishi A1SJ71C24-R2 or A1SJ71QC24 or A1SJ71UC24-R2 or QJ71QC24 to EXTER / E1000 Series. RS232
- 05237: Mitsubishi AJ71QC24 to EXTER / E1000 Series. RS232
- 05238: Moeller PS4-Series to EXTER / E1000 Series. RS232
- 05239: Printer to EXTER / E1000 Series. DB9F to DB25M. RS232
- 05240: Siemens SIMATIC S5 to EXTER / E1000 Series
- 05241: Toshiba PROSEC T-Series to EXTER / E1000 Series. RS232
- 05242: SEW Eurodrive Movi ... to EXTER / E1000 Series. RS232
- 05243: SEW Eurodrive Movi ... to CIMREX and EXTER / E- and E1000 Series with CAB8. RS485
- 05244: SEW Eurodrive Movi .... to EXTER / E1000 Series. RS485
- 05245: Keyence KV Series to EXTER / E1000 Series. RJ11 to DB9F. RS232
- 05246: Intelligent Actuator SuperSEL to EXTER / E1000 Series. Centronics25 to DB9F. RS232
- 05250: Festo/Beck IPC/FEC RJ Connector to EXTER / E1000 Series. RS232
- 05251: Festo/Beck IPC/FEC to EXTER / E1000 Series. RS232
- 05252: Control Techniques Unidrive to EXTER / E1000 Series. RS485
- 05273: Cable Adapter for CIMREX and EXTER / E- and E1000 Series to Old Cable Assembly for MAC50/90/200. RS422
- ABS EXTER/E1000 Series Marine Certificate
- Battery (MS614S) in EXTER K10m and EXTER K20m / E1012 and E1022
- CAB10: Allen-Bradley SLC5 and 500 to CIMREX and EXTER / E- and E1000 Series RS485 to RS422
- CAB11: MPI Adapter between Siemens S7 and CIMREX and EXTER / E- and E1000 Series MPI to RS232
- CAB12: 9-Pin Male/Female D-Sub Adapter. EXTER / E1000 Series to CIMREX / E- Series Cables RS232
- CAB14: Matsushita FPO/M/2/2SH to CIMREX and EXTER / E- and E1000 Series with CAB12. RS232
- CAB15: CANopen Adapter. CIMREX and EXTER / E- and E1000 Series. RS422
- CAB20: Siemens S7-200 to CIMREX and EXTER / E- and E1000 Series. RS422
- CAB23: Extra RS422 Cable Between CIMREX and EXTER / E- and E1000 Series to CAB15. RS422
- CAB25: Shielded 24 V DC Supply Cable to CIMREX and EXTER / E- and E1000 Series
- CAB30: Programming Cable EXTER / E1000 Series. RS232
- CAB31: Allen-Bradley Micrologix to EXTER / E1000 Series. RS232
- CAB32: Omron C/CS1 to EXTER / E1000 Series. RS232
- CAB33: Matsushita FP0/M/2/2SH to EXTER / E1000 Series. RS232
- CAB34: Mitsubishi Q-CPU to EXTER / E1000 Series
- CAB6: CIMREX and EXTER / E- and E1000 Series to PC/PC-Compatible. RS422
- CAB9: CIMREX and EXTER / E- and E1000 Series to Unit with RJ45 Connector. RS422
- Cable Guide for EXTER and CIMREX Operator Panels
- Cables : Cable to connect EXTER to a PC
- CAN J1939 Expansion Module for iX and EXTER/E1000 Operator Panels (MAEN962/MADE962)
- CCS - China Classification Society of EXTER and iX Panel PIEN287
- Certificate of Compliance for EXTER and E1000 UL1604/508/60950-1
- Communication between EXTER and Honeywell HC900 controller
- Compass Safe Distance for EXTER Operator Panels (PIEN168A)
- Configuration of a modem PPP connection between EXTER and a PC with Windows XP (KI00251)
- Converting a CIMREX Project to EXTER (KI00256)
- Cyclic Salt Mist EXTER T70, EXTER T100, EXTER T150 EMC
- Declaration of Conformity ABS for EXTER-bl and EXTERsr-bl
- Declaration of Conformity CE for EXTER-bl
- Declaration of Conformity CE for EXTER-bl and EXTERsr-bl
- Declaration of Conformity for EXTER Operator Panels
- DNV for EXTER Operator Panels
- Do the Tx (timeout) and Rx (retries) commands work for EXTER / E1000?
- Does EXTER or CIMREX series / E1000 or E-series withstand acetone vapour?
- Does the Tx (timeout) and Rx (retries) command work for EXTER?
- Downloading Projects in the EXTER Operator Panels (SUEN264)
- Driver MELSEC QnA/Q-C24: What settings are needed in QC24 to be to communicate with an EXTER?
- E1000 / Exter - Is it possible to use an USB mouse on keypad panels?
- E1032/Exter K30: Terminal reboot when changing blocks
- EAR Approval for the EXTER Operator Panels
- Environmental Impact Report for EXTER Operator Panels (PIEN144B)
- Environmental Impact Report for iX Panels and EXTER Operator Panels (PIEN144C)
- EXTER Demo Projects
- EXTER E1000 ABS PDA Certification 14-LD356481-1-PDA (PROD CERT - 1032465 - 1 - A1) - 1
- EXTER E1000 DoC CE, RoHS
- EXTER K100 / E1100 Outline Drawing (pdf and dwg)
- EXTER K100 / E1100 Panel Cut-Out (pdf and dwg)
- EXTER K10m / E1012 Outline Drawing (pdf, dwg)
- EXTER K10m / E1012 Panel Cut-Out (pdf)
- EXTER K20m / E1022 Outline Drawing (pdf, dwg)
- EXTER K20m / E1022 Panel Cut-Out (pdf)
- EXTER K30m / E1032 Outline Drawing (pdf and dwg)
- EXTER K30m / E1032 Panel Cut-Out (pdf and dwg)
- EXTER K60 / E1060 Outline Drawing (pdf)
- EXTER K60 / E1060 Panel Cut-Out (pdf and dwg)
- EXTER K70 / E1070 Outline Drawing (pdf and dwg)
- EXTER K70 / E1070 Panel Cut-Out (pdf and dwg)
- EXTER M70 Outline Drawing
- EXTER T100 / E1101 Outline Drawing (pdf and dwg)
- EXTER T150 / E1151 Panel Cut-Out (pdf and dwg)
- EXTER T40/T40m / E1041/E1043 Outline Drawing (pdf and dwg)
- EXTER T40/T40m / E1041/E1043 Panel Cut-Out (*.pdf and *.dwg)
- EXTER T60 / E1061/E1063 Outline Drawing (pdf)
- EXTER T60 / E1061/E1063 Panel Cut-Out (pdf and dwg)
- EXTER T70 / E1071 Outline Drawing (pdf and dwg)
- EXTER T70 / E1071 Panel Cut-Out (pdf and dwg)
- Germanischer Lloyd Marine Approval for EXTER/E1000 Series (new 2013)
- Green Passport EXTER/ E1000
- IACS E10 for EXTER Operator Panels
- IACS E10 for EXTER-bl Operator Panels
- iX_EXTER_E1000_Environmental
- Manufacturer's Declaration: ABS for EXTER-bl and EXTERsr-bl
- MTBF (Mean Time Between Failures) for EXTER Operator Panels
- NEMA 4X for EXTER Operator Panels
- Operating temperature testing for EXTER
- Optimizing Your EXTER Project in Information Designer
- PCN EXTER remove coating on CPU and Power board (PDM_CDOC - 1030026 - 1 - A1) - 1
- PPP with Exter and GSM modems
- Problem to printout text strips on EXTER K100
- Problem with CF memory card detection in Exter/E1000 panels
- Release Notes EXTER/E1000 post 1.52 release
- Remote Access Viewer v1.5.4, for Exter/E1000 - TxA/TxB/TAxx - X2 panels
- RINA for EXTER Operator Panels
- Russian Maritime Register of Shipping for EXTER Operator Panels
- Supported voltage and power peaks for E1000/Exter teminals
- Trade compliance Exter- / E1000-series, PI00137
- UL E192000 for X2Base ,TxA, Exter
- Web Functionality in the EXTER Operator Panels
- Which material will be used for the EXTER adapter plates?
Find a replacement for your existing EXTER/E1000 panel in this table!
Limited availability
EXTER K70
6,5'' - 640 x 480 pixel TFT keypad HMI
EOL - End Of Life:
2018-01-01
LTB - Last Time Buy:
2018-12-31
LTD - Last Time Delivery:
2019-03-31
LTR - Last Time Repair:
2022-12-31
Replacement Parts: