BCS-NX3020
High-speed CPU
- High-speed processing Cpu, 200 PID loops in 1ms
- Application memory capacity, 6MB
- Persistent memory, 112KB
- Max. rack I/O modules, 128
- Com. Interfaces, 2xEthernet/2xSerial
- Fieldbus connection, EtherCat/Ethernet/IP/Profibus DP/Modbus TCP/RTU/OPC UA/DA/IEC60870-5-104
- Web server diagnostics
Facts
General description
Article number | 66.014.121-2 |
Warranty | 2 year |
Mechanical
Certificates | CE, ROHS, UL, DNV |
Module dimensions (W x H x D) | 36.00 x 114.63 x 115.30 mm |
Net weight | 350 g |
Power
Current consumption from backplane rack | 1000 mA |
System
Hot Swap | Yes |
One Touch Diag (OTD) | Yes |
Status and diagnostics indication | Yes |
Redundancy | No |
Maximum nbr of expansion racks | 24 |
Maximum nbr of modules | 128 |
Clock synchronization (SNTP) | SNTP |
Network monitor (SNMP) | SNMPv1, SNMPv2c, SNMPv3 |
Program memory | 6MB |
Source code memory | 80MB |
User files memory | 32MB |
Communication
Communication protocols | EtherCat Master, Ethernet/IP Scanner/Adapter, ModbusTCP client/server, Modbus RTU master/slave, User defined protocol, IEC60870-5-104 server, OPC UA/DA server |
Ethernet interface | 2xRJ45 10/100 Mbps |
Serial interface | 1xRS-232, 1xRS422/485 |
Smart Engineering Resources
Resources
Firmware
- BCS Nexto - NX30x0 CPU Firmware 1.10.8.0 (current version)
- BCS Nexto - Cpu Firmware 1.8.13.0/1.9.29.0 (transition version)
Program examples/Start-up
- BCS Tools Nexto - Firstscan bit
- BCS Tools Nexto -Programming path setup (KI00345B)
- BCS Tools Nexto - Program example datalogging function
- BCS Tools Nexto - Connecting Nexto and iX with Modbus TCP (KI00360)
- BCS Tools Nexto - Compile and Project transfer (KI00346)
- BCS Tools Nexto - Program example read write real time clock
- BCS Tools Nexto - Program example read write IP address information with functionblock
- BCS Tools Nexto - Program example read task and application information
- BCS Tools Nexto - Program example PID functionblock
- Quick start guide - Connect X2 HMI with Nexto PLC, SUEN00414
- Program example BCS Tools and iX: Nexto communication with BFI by EtherCAT
- BCS Tools/Nexto - Modbus TCP and Crevis I/O, init ST-3702
- Program example BCS Tools and iX: Nexto Xpress communication with BFI by Modbus RTU.
- Kom i gang med Nexto XPress - Grunnleggende (Norwegian)
- Get Started with Nexto Xpress - MQTT communication
- Get Started with Nexto Xpress - The Basics
- Get Started with Nexto Xpress - High speed datalogging
- BCS Tools, MODBUS Symbol Server/Client
- Get started with Nexto Xpress - IEC60870-5-104
- Get Started with Nexto Xpress - Database communication
Adverts
Catalogues
Certificates
- BCS Nexto modular - DNV approval
- BCS Nexto/Nexto Xpress - UL/cUL certificate
- BCS Nexto Modular - CE EMC/LVD Declaration
- BCS Nexto Modular - UKCA Declaration
Information document
Manuals
- BCS NX3010/3020/3030 - Installation Guide
- BCS-NX3020 - User Manual
- BCS Nexto modular/Nexto Xpress - PID advanced library
- BCS Tools - User Manual
- BCS Tools - Programming Manual
- BCS Tools - Datasheet
- BCS NX940x - User's manual (Connectors of Nexto Series)
- BCS NX92xx - User's manual (RJ45-RJ45 Cables)
- BCS Nexto Series - User Manual
Knowledge
- BCS Tools Nexto - Task priority and scheduling
- BCS Tools Nexto -After compilation Memory 0 - 6 are presented, what do these mean?
- BCS Tools Nexto - Diagnostic variables with IP address information
- Clarification about the force function in CODESYS
- BCS Tools Nexto - Task information and I/O update synchronization
- BCS Tools Nexto - Download Boot Application during RUN
- BCS Tools - Using the library NextoPID and Util at the same time causes a naming conflict for the PID instruction
- BCS Tools Nexto - Add PID Loops online
- BCS NX3010/3020/3030 - Support of Flood attacks on local and external Ethernet ports
- BCS NX3010/3020/3030 - Real Time Clock (backup time)
- BCS Nexto modular/Nexto Xpress - Firmware update procedure
- CODESYS/BCS Tools - Support of REAL (32-bit) and LREAL (64-bit)
- BCS Nexto - How to update firmware in a Nexto CPU in RUN mode
- Nexto serial pinout for COM ports
- Nexto - Reserved ports
- BCS-Nexto/Nexto Xpress - Number of supported ARTI connections
- BCS Tools - The address %QBxxxxx not defined in any device
- BCS Tools - OPC connection to the CPU or the simulator in BCS Tools.
- Nexto Modular/Nexto Xpress - TLS support
- Nexto modular/Nexto Xpress - MQTT TLS certificate validity check
- How to download Free software packages from SmartStore
- BCS Nexto - ARTI/OPC communication
- Example of a Modbus/TCP client via PLC code using the Oscat library
- BCS Nexto Xpress/Modular - MQTT version
- LTB Life Cycle Notification BCS-NX940x spareparts
- BCS Nexto/Nexto Xpress - MQTT certificate support
- Nexto I/O update with EtherCat master
- Nexto - Persistent variables loose their value if the name of the application changes
- Nexto - Check operating status of I/O modules
- BCS Tools - Edit CSV files with Excel 2013 or newer might destroy and make the csv files unusable for BCS Tools
Data sheets
Software
Drawings
Configuration files
Limited availability
BCS-NX3020
High-speed CPU
EOL - End Of Life:
-
LTB - Last Time Buy:
-
LTD - Last Time Delivery:
-
LTR - Last Time Repair:
-
Replacement Parts: