System Requirements

This chapter describes how to define the System Requirements in iX Developer.

In iX Developer 3, you cannot configure system settings directly as in previous versions. Instead, you define System Requirements that are evaluated and then reserved by the OS3 operating system. If the requirements are not met, the iX App is installed on the HMI panel but cannot run.

Select the check box for each requirement that the iX App needs, and enter the settings for it. All settings are optional, and a requirement that is not selected is not included.

Tip

  • For information on the HMI panels system settings, see App System Requirements in the OS3 User Guide.

  • When converting a project from iX Developer 2 to iX Developer 3, you can manually import the system settings from iX Developer 2 to the System Requirements. For instructions, see Migrate System Settings from iX2 to iX3 in the X2 to X3 – Transition Guide.

Parameter

Description

LAN A and LAN B

The network settings for each network interface on the HMI panel.

  • Enable DHCP: Set to On if the interface obtains its network settings from a DHCP server.

  • IP-address, Subnet mask, Default gateway, Primary DNS Server and Secondary DNS Server: The required network settings for the interface.

All fields are optional, but if you enter either IP-address or Subnet mask, both are required.

SNTP Synchronization

The time synchronization against an external SNTP (Simple Network Time Protocol) server.

  • Enable SNTP: Set to On if the panel clock needs to be synchronized with an SNTP server.

  • Server address: The name of the SNTP server.

  • Update interval in minutes: The interval between synchronizations.

Serial Ports (only for HMI panel targets)

Select the check box for each COM port the iX App needs, and set Type to Any, RS-232, RS-422, RS-485 or CAN. To add a port that is not listed, select Add COM Port.

The number of available ports and possible configuration differ depending on selected target. For configuration instructions, see Serial Ports in the OS3 User Guide.

Power Saving

The automatic turn-off of the display. This reduces backlight usage, helping extend the lifespan of HMI panels.

  • Enable power saving: Set to On to turn off the display automatically.

  • Timeout: The time before the display turns off.

TCP Server Port and UDP Server Port

The server ports to reserve for incoming traffic. Enter one port number, or a range of ports as the first and last port number separated by a hyphen, for example 8080-10203. To reserve more ports, select Add Port.